Phidget Stepper.lvlib:StepperSetCurrentLimit.vi

The current through the motor will be limited by the StepperCurrentLimit.


For more information about StepperCurrentLimit, visit our Stepper API Guide.

Phidget Stepper.lvlib:StepperSetCurrentLimit.vi

cu64

Device In

Device # Identification

cerrcodeclst

error in (no error)

error in can accept error information wired from VIs previously called.

cdbl

Current Limit

The current limit value

Units: amperes (A)

1063_0 (ver: 100) Bipolar Stepper Controller: Min: 0.0542 Max: 2.492 Default: 1

1063_1 (ver: 100, 101) Bipolar Stepper Controller: Min: 0.0542 Max: 2.492 Default: 1

1067_0 (ver: 200, 201, 202, 203, 204, 205, 206) Bipolar Stepper Controller: Min: 0 Max: 4 Default: 1

STC1000_0 (ver: 100, 101) Bipolar Stepper Controller: Min: 0 Max: 4 Default: 1

STC1000_0 (ver: 110, 111, 112, 113, 114, 121, 122) Bipolar Stepper Controller: Min: 0 Max: 4 Default: 1

STC1001_0 (ver: 100, 101) Bipolar Stepper Controller: Min: 0 Max: 2.5 Default: 1

STC1001_0 (ver: 110, 111, 112, 113, 114, 115, 121, 122) Bipolar Stepper Controller: Min: 0 Max: 2.5 Default: 1

STC1002_0 (ver: 101, 102) Bipolar Stepper Controller: Min: 0 Max: 8 Default: 1

STC1002_0 (ver: 110, 111, 112, 113, 114, 121, 122) Bipolar Stepper Controller: Min: 0 Max: 8 Default: 1

STC1003_0 (ver: 100, 101) Bipolar Stepper Controller: Min: 0 Max: 4 Default: 1

STC1003_0 (ver: 110, 111, 112, 113, 114, 121, 122) Bipolar Stepper Controller: Min: 0 Max: 4 Default: 1

STC1003_1 (ver: 201, 221, 222) Bipolar Stepper Controller: Min: 0 Max: 4 Default: 1

STC1005_0 (ver: 100) Bipolar Stepper Controller: Min: 0 Max: 4 Default: 1

STC1005_0 (ver: 110, 111) Bipolar Stepper Controller: Min: 0 Max: 4 Default: 1

iu64

Device Out

Same as Device In

ierrcodeclst

error out

error out passes error or warning information out of a VI to be used by other VIs.